Test Description
WARNING: This page is about a different car, the 2004 Chevrolet Corvette. However, it is still accessible from the selected car via links, so may be relevant.
-
The numbers below refer to the step numbers on the diagnostic table.
- 1: This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
- 2: This step measures the performance of the A/C system.
- 3: This step is to allow for vehicle variations as well as high ambient temperatures.
Air Conditioning (A/C) System Performance Test
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
|
IMPORTANT:
|
||||
| 1 |
|
More than 16° C (60° F) - 345 kPa (50 psi) More than 24° C (75° F) - 483 kPa (70 psi) More than 33° C (90° F) - 690 kPa (100 psi) |
Go to Step 2 | Go to Leak Testing |
| 2 |
IMPORTANT:
Record the relative humidity and the ambient air temperature at the time of the test.
IMPORTANT:
Press the RESET button, before using the print function of the J 43600
. See Special Tools and Equipment .
|
- | Go to Step 8 | Go to Step 3 |
| 3 | If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? |
- | Go to Step 8 | Go to Step 4 |
| 4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A | Go to Step 5 |
| 5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B | Go to Step 6 |
| 6 | Are the low and high side pressures both greater than the specified ranges? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C | Go to Step 7 |
| 7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D | Go to Step 8 |
| 8 | Operate the system in order to verify the test results. Did you find the same results? |
- | System OK | Go to Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic |
A/C Performance Table
| Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
|---|---|---|---|---|
| Low Side | High Side | |||
| 13-18° C (55-65° F) | 0-100% | 211-241 kPa (31-35 psi) | 500-740 kPa (73-107 psi) | 8° C (46° F) |
| 19-23° C (66-75° F) | Below 40% | 193-223 kPa (28-32 psi) | 780-1090 kPa (106-167 psi) | 8° C (46° F) |
| Above 40% | 209-239 kPa (30-35 psi) | 730-1050 kPa (106-167 psi) | 9° C (48° F) | |
| 24-29° C (76-85° F) | Below 35% | 172-214 kPa (25-31 psi) | 1020-1227 kPa (148-178 psi) | 9° C (48° F) |
| 35-60% | 199-229 kPa (29-33 psi) | 970-1300 kPa (141-189 psi) | 9° C (48° F) | |
| Above 60% | 207-237 kPa (30-34 psi) | 1020-1500 kPa (148-218 psi) | 10° C (50° F) | |
| 30-35° C (86-95° F) | Below 30% | 210-240 kPa (31-35 psi) | 1130-1520 kPa (164-221 psi) | 10° C (50° F) |
| 30-50% | 208-238 kPa (30-35 psi) | 1190-1670 kPa (173-242 psi) | 11° C (52° F) | |
| Above 50% | 205-235 kPa (30-35 psi) | 1280-1910 kPa (186-277 psi) | 11° C (52° F) | |
| 36-40° C (96-105° F) | Below 20% | 226-256 kPa (33-37 psi) | 1280-1650 kPa (186-240 psi) | 12° C (54° F) |
| 20-40% | 218-248 kPa (32-36 psi) | 1360-1870 kPa (197-271 psi) | 12° C (54° F) | |
| Above 40% | 211-241 kPa (31-35 psi) | 1520-2100 kPa (221-305 psi) | 12° C (54° F) | |
| 41-46° C (106-115° F) | Below 20% | 238-268 kPa (35-39 psi) | 1460-1830 kPa (212-267 psi) | 13° C (55° F) |
| Above 20% | 226-256 kPa (33-37 psi) | 1570-2100 kPa (228-306 psi) | 13° C (55° F) | |
| 47-49° C (116-120° F) | Below 30% | 238-268 kPa (35-39 psi) | 1750-2090 kPa (254-303 psi) | 14° C (57° F) |