Air Recirculation Malfunction
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2004 Oldsmobile Bravada, 2004 GMC Envoy XUV, 2004 GMC Envoy XL, 2004 GMC Envoy, and 2004 Chevrolet TrailBlazer. However, it is still accessible from the selected car via links, so may be relevant.
Air Recirculation Malfunction
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. |
|||
| 1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Manual |
| 2 |
|
Go to Step 3 | Go to Step 10 |
| 3 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 4 |
| 4 |
|
Go to Step 10 | Go to Step 5 |
| 5 |
|
Go to Step 6 | Go to Step 11 |
| 6 | Test the ground circuit of the recirculation actuator for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 7 |
| 7 | Test the recirculation door control circuit of the recirculation actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 8 |
| 8 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? |
Go to Step 14 | Go to Step 9 |
| 9 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 12 |
| 10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 14 | Go to Step 13 |
| 11 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 14 | - |
| 12 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? |
Go to Step 14 | - |
| 13 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? |
Go to Step 14 | - |
| 14 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |