Test Description
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2004 Oldsmobile Bravada, 2004 GMC Envoy XUV, 2004 GMC Envoy XL, 2004 GMC Envoy, and 2004 Chevrolet TrailBlazer. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 3: Tests for the proper operation of the circuit in the high voltage range. If the jumper fuse opens when you perform this test, the circuit is shorted to ground.
- 7: Tests for the proper operation of the circuit in the high voltage range. If the jumper fuse opens when you perform this test, the circuit is shorted to ground.
- 8: Tests for a short to voltage in the 5-volt reference circuit.
- 9: Tests for a high resistance or for an open in the low reference circuit.
- 10: This step tests for an open on the low reference circuit that is common to all of the actuators. Choose the easiest HVAC door actuator that set a DTC to start the diagnosis.
- 11: Disconnecting each actuator, one at a time, isolates the disconnected actuators signal circuit from the 5 volt reference circuit that is common to all the actuators.
DTC B0229, B0414, B0424, B3761, or B3770
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views |
||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 | Is DTC B1375 set as a current DTC? | - | Go to Diagnostic Trouble Code (DTC) List | Go to Step 3 |
| 3 | With a scan tool, observe the Heating and Air Conditioning DTC list. Does the scan tool indicate that at least 2 of the following DTC B0229, B0414, B0424, B3761 and B3770 are set as current DTC? |
- | Go to Step 10 | Go to Step 4 |
| 4 |
|
5-250 counts | Go to Step 5 | Go to Step 6 |
| 5 |
|
- | Go to Diagnostic Aids | Go to Step 19 |
| 6 |
|
5 counts | Go to Step 7 | Go to Step 17 |
| 7 |
|
230 counts | Go to Step 8 | Go to Step 15 |
| 8 |
|
5.5 V | Go to Step 9 | Go to Step 14 |
| 9 |
|
5 Ω | Go to Step 22 | Go to Step 18 |
| 10 |
|
- | Go to Step 11 | Go to Step 18 |
| 11 |
|
- | Go to Step 13 | Go to Step 12 |
| 12 | Test the 5-volt reference circuit of the appropriate HVAC door actuator for an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 23 |
| 13 | Test the appropriate door position signal circuit of the HVAC door actuator for a short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 22 |
| 14 | Test the 5-volt reference circuit of the appropriate HVAC door actuator for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 23 |
| 15 | Test the 5-volt reference circuit of the appropriate HVAC door actuator for a short to ground, for a high resistance, or for an open. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 16 |
| 16 | Test the appropriate door position signal circuit of the HVAC door actuator for a short to ground, for a high resistance, or for an open. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 23 |
| 17 | Test the appropriate door position signal circuit of the HVAC door actuator for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 22 |
| 18 |
|
- | Go to Step 26 | Go to Step 23 |
| 19 |
|
- | Go to Step 23 | Go to Step 20 |
| 20 | Test the door control circuit of the appropriate HVAC door actuator for a short to voltage, for a short to ground, or for an open. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 21 |
| 21 | Test the ignition 3 voltage circuit of the appropriate HVAC door actuator for an open or a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 22 |
| 22 | Inspect for poor connections at the harness connector of the appropriate HVAC door actuator. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 24 |
| 23 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 26 | Go to Step 25 |
| 24 |
IMPORTANT:
Perform the calibration procedure for HVAC door actuators. Replace the HVAC door actuator. Refer to the appropriate replacement procedure:Did you complete the replacement? |
- | Go to Step 26 | - |
| 25 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? |
- | Go to Step 26 | - |
| 26 |
|
- | Go to Step 3 | System OK |