Blower Motor Inoperative
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2004 Oldsmobile Bravada, 2004 GMC Envoy XUV, 2004 GMC Envoy XL, 2004 GMC Envoy, and 2004 Chevrolet TrailBlazer. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. |
|||
| 1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
Go to Blower Motor Malfunction | Go to Step 3 |
| 3 |
|
Go to Step 10 | Go to Step 4 |
| 4 |
|
Go to Step 8 | Go to Step 5 |
| 5 | Connect a test lamp between the battery positive voltage circuit of the blower motor control processor and a good ground. Does the test lamp illuminate? |
Go to Step 7 | Go to Step 6 |
| 6 | Repair the battery positive voltage circuit of the blower motor control processor. Refer to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 16 | - |
| 7 | Repair the ground circuit of the blower motor control processor. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 16 | - |
| 8 |
|
Go to Step 11 | Go to Step 9 |
| 9 | Test the blower motor speed control circuit of the blower motor control processor for an open, short to ground, or short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 16 | Go to Step 12 |
| 10 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 16 | Go to Step 13 |
| 11 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 16 | Go to Step 14 |
| 12 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 16 | Go to Step 15 |
| 13 | Replace the blower motor. Refer to Blower Motor Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
Go to Step 16 | - |
| 14 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? |
Go to Step 16 | - |
| 15 |
IMPORTANT:
Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement .Did you complete the replacement? |
Go to Step 16 | - |
| 16 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 2 |