LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 1418 (HVAC Systems - Automatic) >> Diagnostic Information and Procedures >> Actuator Recalibration >> Re-Calibrating Actuators (Auxiliary HVAC)

Re-Calibrating Actuators (Auxiliary HVAC)

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2004 Oldsmobile Bravada, 2004 GMC Envoy XUV, 2004 GMC Envoy XL, 2004 GMC Envoy, and 2004 Chevrolet TrailBlazer. However, it is still accessible from the selected car via links, so may be relevant.

When replacing the auxiliary HVAC control module it will be necessary to allow the auxiliary HVAC control module to perform a calibration process. When installing the auxiliary HVAC control module be sure to perform the following:

  1. Place the ignition switch to the OFF position.
  2. Disconnect the scan tool.
  3. Install the auxiliary HVAC control module.
  4. Connect all previously disconnected components.
  5. Place the ignition switch in the RUN position.
  6. Wait 40 seconds for the auxiliary HVAC control module to self-calibrate.
  7. Verify that no DTCs have set as current DTCs.

When replacing an auxiliary HVAC actuator it will be necessary to allow the auxiliary HVAC control module to perform a calibration process. When installing the auxiliary HVAC actuator be sure to perform one of the following:

Preferred Method (w/Scan Tool)

  1. Clear all DTCs.
  2. Place the ignition switch in the OFF position.
  3. Install the auxiliary HVAC actuator.
  4. Connect all previously disconnected components.
  5. Place the ignition switch in the RUN position.
  6. With the scan tool, initiate the HVAC Actuator Recal. feature of the RHVAC/RSA module Special Functions menu.
  7. Verify that no DTCs have set as current DTCs.

Alternate Method (w/o Scan Tool)

  1. Clear all DTCs.
  2. Place the ignition switch to the OFF position.
  3. Install the auxiliary HVAC actuator.
  4. Connect all previously disconnected components.
  5. Remove the HVAC B fuse for a minimum of 10 seconds.
  6. Install the HVAC B fuse.
  7. Place the ignition switch in the RUN position.
  8. Wait 40 seconds for the auxiliary HVAC control module to self-calibrate.
  9. Verify that no DTCs have set as current DTCs.