Installation Procedure
WARNING: This page is about a different car, the 2004 GMC Envoy XUV, 2004 GMC Envoy XL, 2004 Chevrolet TrailBlazer, and 2004 Buick Rainier. However, it is still accessible from the selected car via links, so may be relevant.
- Install the air cleaner outlet duct.
- Install the air cleaner outlet duct bolt.
Tighten: Tighten the bolt to 10 N.m (89 lb in).
- Tighten the clamps at the following:
- MAF/IAT sensor.
- Throttle body
Tighten: Tighten the clamps to 7 N.m (62 lb in).
NOTE:
Refer to Fastener Notice in Cautions and Notices.