Circuit Description
The fuel level sender changes resistance based on fuel level. The powertrain control module (PCM) monitors the signal circuit of the fuel level sender in order to determine fuel level. When the fuel tank is full, the sender resistance is high and the PCM senses a high signal voltage. When the fuel tank is empty, the sender resistance is low and the PCM senses a low signal voltage. The PCM uses the signal circuit of the fuel level sender in order to calculate the total remaining fuel, percent, in the tank. The PCM sends the fuel level percent via the class 2 serial data circuit to the instrument cluster in order to control the fuel gage. The fuel level information is also used for misfire and evaporative emissions (EVAP) diagnostics.
This diagnostic tests for a stuck fuel level sender signal. The PCM sets this DTC if the fuel level sender signal appears to be stuck based on a lack of signal variation expected during normal operation.