Blower Motor Inoperative

WARNING: This page is about a different car, the 2004 Pontiac Vibe. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Inoperative

Step Action Yes No
Schematic Reference: HVAC Schematics 
Connector End View Reference: HVAC Connector End Views 
1 Did you review the Air Delivery Description and Operation  and the Air Temperature Description and Operation  perform the necessary inspections? Go to Step 2  Go to Symptoms - HVAC Systems - Manual 
2 Operate the blower motor at each speed.
Does the blower motor operate at any speed?
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems Go to Step 3 
3
  1. Disconnect the blower motor connector.
  2. Connect a test lamp across the blower motor connector.
  3. Start the engine.
  4. Turn the blower switch to any position except OFF.
Does the test lamp light?
Go to Step 12  Go to Step 4 
4 Test the blower motor supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 5 
5 Test the blower motor ground circuit for an open between the blower motor and S223. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 6 
6 Test that the heater relay is open between terminals 3 and 5 and that there is continuity between terminals 3 and 4.
Did the relay test OK?
Go to Step 7  Go to Step 11 
7 Test the heater relay coil and switch supply voltage circuits for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 8 
8 Test the heater relay control circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 9 
9 Test the blower switch ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 10 
10 Inspect for a poor connection at the harness connector of the blower switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 13 
11 Inspect for a poor connection at the harness connector of the heater relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 14 
12 Inspect for a poor connection at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 16  Go to Step 15 
13 Replace the blower switch. Refer to Blower Switch Replacement .
Did you complete the replacement?
Go to Step 16  -
14 Replace the heater relay. Refer to Blower Motor Relay Replacement .
Did you complete the replacement?
Go to Step 16  -
15 Replace the blower motor. Refer to Blower Motor Replacement .
Did you complete the replacement?
Go to Step 16  -
16 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 3