Air Recirculation Malfunction (Always in Recirculation Position)

WARNING: This page is about a different car, the 2004 Pontiac Vibe. However, it is still accessible from the selected car via links, so may be relevant.
Reference Table

Symptom Causes
Recirculation inoperative
  • Open in the outside air signal circuit.
  • Open in the recirculation signal circuit.
  • Open or short to ground in the recirculation switch supply voltage circuit.
  • Open in the A/C/Fresh/Recirculation switch ground circuit.
Always in recirculation position
  • Short to ground in the outside air signal circuit.
  • Short to B+ in the recirculation signal circuit.
Always in fresh position
  • Short to B+ in the outside air signal circuit.
  • Short to ground in the in the recirculation signal circuit.
Air Recirculation Malfunction (Always in Recirculation Position)

Step Action Yes No
Schematic Reference: HVAC Schematics 
Connector End View Reference: HVAC Connector End Views 
DEFINITION: Always in recirculation position.
1 Did you review the Air Delivery Description and Operation  and the Air Temperature Description and Operation  and perform the necessary inspections? Go to Step 2  Go to Symptoms - HVAC Systems - Manual 
2
  1. Start the engine.
  2. Open the instrument panel compartment.
  3. Observe the recirculation actuator while pressing the recirculation switch.
Does the recirculation actuator operate?
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems Go to Step 3 
3 Test the fresh/recirculation switch. There should be continuity between terminals 4 and 5 in the recirculation position (switch depressed) and between terminals 4 and 2 in the outside air position (switch not depressed).
Did the switch test OK?
Go to Step 4  Go to Step 8 
4 Test the outside air signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 9  Go to Step 5 
5 Test the recirculation signal circuit for a short to B+. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 9  Go to Step 6 
6 Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 9  Go to Step 7 
7 Replace the recirculation actuator. Refer to Recirculation Actuator Replacement .
Did you complete the replacement?
Go to Step 9  -
8 Replace the recirculation switch. Refer to HVAC Control Assembly Replacement (Control Assembly)  in Stationary Windows.
Did you complete the replacement?
Go to Step 9  -
9 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 3