Circuit Description
The right fuel level sensor measures fuel level changes within the right fuel tank.
When the fuel level is high the sensor signal voltage is high. When the fuel level is low the sensor signal voltage is low.
The powertrain control module (PCM) uses inputs from the left fuel level sensor and the right fuel level sensor in order to calculate the total fuel remaining in both fuel tanks. The PCM sends this information via class 2 to the IPC.
This diagnostic tests for a stuck right fuel level sensor signal. If the PCM determines that the fuel level (right tank) signal appears to be stuck based on a lack of signal variation expected during normal operation, this DTC sets.
The left tank fuel pump also supplies a small amount of pressurized fuel to the right fuel tank siphon jet pump through the auxiliary fuel feed rear pipe. The pressurized fuel creates a venturi action inside the siphon jet pump. The venturi action causes the fuel to be drawn out of the right fuel tank. Fuel is then transferred from the right fuel tank to the left fuel tank through the auxiliary fuel return rear pipe. The fuel system is designed to maintain a greater level in the left fuel tank then in the right fuel tank when the electric fuel pump is operating. The fuel transfer rate from the left fuel tank to the right fuel tank is less than the transfer rate from the right fuel tank to the left fuel tank. Therefore, with the electric fuel pump operating, the left fuel tank level should be higher than the right fuel tank level.
The fuel level in the fuel tanks equalize when the following occur:
- The electric fuel pump is not operating.
- The fuel level is greater than 50 percent.