Air Conditioning (A/C) Diagnostics - Pressure Zone D
WARNING: This page is about a different car, the 2004 Pontiac Aztek and 2004 Buick Rendezvous. However, it is still accessible from the selected car via links, so may be relevant.
Air Conditioning (A/C) Diagnostics - Pressure Zone D
| Step | Action | Yes | No |
|---|---|---|---|
DEFINITION: The low side pressure is lower than normal and the high side pressure is higher than normal.
|
|||
| 1 | Were you sent here from the A/C System Performance Test? | Go to Step 2 | Go to Air Conditioning (A/C) System Performance Test |
| 2 |
CAUTION:
Refer to Moving Parts and Hot Surfaces Caution
in Cautions and Notices. Feel the liquid line before the expansion device.Is the liquid line cold before the expansion device? |
Go to Step 3 | Go to Step 8 |
| 3 | Feel along the surfaces of the following high side components:
Did you detect an abrupt drop in temperature along the surfaces of any of the listed components? |
Go to Step 7 | Go to Step 4 |
| 4 |
|
Go to Step 11 | Go to Step 5 |
| 5 | Feel along the surfaces of the following low side components:
Did you feel an abrupt temperature change along the surfaces of any of the listed components? |
Go to Step 7 | Go to Step 6 |
| 6 | Feel along the surfaces of the low and the high side components.
Are the temperatures of these components only mildly warm? |
Go to Step 14 | Go to Step 8 |
| 7 |
|
Go to Step 9 | - |
| 8 |
|
Go to Step 9 | Go to Step 10 |
| 9 | Recharge the A/C system. Refer to Refrigerant Recovery and Recharging . Is the cooling performance improved? |
Go to Step 21 | Go to Step 10 |
| 10 |
|
Go to Step 21 | - |
| 11 | The expansion device is restricted. Replace the expansion device. Refer to Thermal Expansion Valve Replacement . Are metal flakes present? |
Go to Step 12 | Go to Step 13 |
| 12 |
|
Go to Step 18 | Go to Step 20 |
| 13 | If the expansion device was restricted with a brown or black residue, perform the following procedure:
Are the repairs complete? |
Go to Step 21 | - |
| 14 |
|
Go to Step 15 | Go to Step 19 |
| 15 |
|
Go to Step 17 | Go to Step 16 |
| 16 | If the expansion device does not show any signs of damage or debris, perform the following procedure:
Did a large amount of debris collect in the shop towel? |
Go to Step 18 | Go to Step 19 |
| 17 |
|
Go to Step 12 | Go to Step 13 |
| 18 | If a large amount of debris was collected in the shop towel from the suction hose, replace the receiver dehydrator. Refer to Receiver Dehydrator Replacement . Is the repair complete? |
Go to Step 19 | - |
| 19 | Install the suction and the discharge hoses. Refer to Suction Hose Replacement (LA1) or Suction Hose Replacement (LY7) and Discharge Hose Replacement (LA1) or Discharge Hose Replacement (LY7) . Are the repairs complete? |
Go to Step 21 | - |
| 20 |
|
Go to Step 21 | - |
| 21 |
|
Go to Step 22 | Go to Air Conditioning (A/C) System Performance Test |
| 22 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic |