LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 1104 (HVAC Systems - Automatic) >> Diagnostic Information and Procedures >> Scan Tool Data List

Scan Tool Data List

WARNING: This page is about a different car, the 2004 Pontiac Aztek and 2004 Buick Rendezvous. However, it is still accessible from the selected car via links, so may be relevant.
BCM Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Switch Inputs On/Off varies
HVAC Control Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
AC Request Outputs Yes/No varies
Ambient Air Temp Data °C/°F varies
Auto Mode Outputs On/Off varies
Auto Button Inputs On/Off varies
Blower Speed Outputs 0 Thru 8 Bars varies
Evaporator Temp Data °C/°F varies
Fan Down Button Inputs On/Off varies
Fan Up Button Inputs On/Off varies
Front Defrost Button Inputs On/Off varies
Inside Air Temperature Data °C/°F varies
Left Temp Door Position Outputs Counts varies
Mode Button Inputs On/Off varies
Mode Door Position Outputs Vent/ Mix-Blend/ Floor/ Bi-Level/ Defrost varies
Off Button Inputs On/Off varies
Rear Defrost Button Inputs On/Off varies
Recirculate Button Inputs On/Off varies
Recirculation Mode Outputs Ambient Air/Recirculate varies
Right Temp Door Position Outputs Counts varies
Selected Air Mode Outputs Warm Up/Defrost/Off varies
Sun Load Sensor Data Counts varies
Vent Button Inputs On/Off varies
PCM Scan Tool Data List 3.4L (LA1)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Off for WOT Engine Data 2 Yes/No varies
A/C Pressure Disable Engine Data 2 Yes/No varies
A/C High Side Pressure Engine Data 2 kPa/Psi varies
A/C High Side Pressure Engine Data 2 Volts varies
A/C Relay Command Engine Data 2/ EGR Data/ Misfire Data On/Off varies
A/C Request Signal Engine Data 2 Yes/No varies
ECM Scan Tool Data List 3.6L (LY7)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Off for WOT Cooling/HVAC Data Yes/No varies
A/C Pressure Disable Cooling/HVAC Data Yes/No varies
A/C High Side Pressure Cooling/HVAC Data Volts varies
A/C Relay Command Cooling/HVAC Data On/Off varies
A/C Request Signal Cooling/HVAC Data Yes/No varies