Test Description
WARNING: This page is about a different car, the 2004 Pontiac Aztek and 2004 Buick Rendezvous. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 3: This step tests for a high resistance in the signal circuit and the ground circuit of the ambient air temperature sensor.
- 10: DTCs may be set in the IPC when you perform this diagnostic table.
Outside Air Temperature Display Inaccurate or Inoperative
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| Schematic Reference: Instrument Cluster Schematics | ||||
| 1 | Did you perform the Instrument Panel Cluster Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - Instrument Cluster |
| 2 |
|
- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
IMPORTANT:
Verify the J 33431-C
resistance settings with a DMM. See Special Tools and Equipment .
|
54°C (130°F) | Go to Step 6 | Go to Step 4 |
| 4 | Test the ambient air temperature sensor signal circuit for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 5 |
| 5 | Test the ground circuit of the ambient air temperature sensor for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 7 |
| 6 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 8 |
| 7 | Inspect for poor connections at the harness connector of the IPC. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 9 |
| 8 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Gage Sensor Replacement (Aztek) or Ambient Air Temperature Gage Sensor Replacement (Rendezvous) . Did you complete the replacement? |
- | Go to Step 10 | - |
| 9 |
IMPORTANT:
Perform the compass calibration and variance procedure on the replacement IPC. Replace the IPC. Refer to Instrument Panel Cluster (IPC) Replacement .Did you complete the replacement? |
- | Go to Step 10 | - |
| 10 |
|
- | System OK | Go to Step 2 |