Diagnostic Aids
WARNING: This page is about a different car, the 2004 Pontiac Aztek and 2004 Buick Rendezvous. However, it is still accessible from the selected car via links, so may be relevant.
The engine will not start when there is a total malfunction of the GMLAN serial data circuits while the engine is not running. The following conditions may cause a total loss of GMLAN data communication:
- Any of the GMLAN High Speed serial data circuits shorted to ground.
- Any of the GMLAN High Speed serial data circuits shorted to voltage.
- A short between GMLAN High Speed serial data circuits.
- An internal malfunction of a module on the GMLAN network that causes a short to voltage or ground.
Scan Tool Does Not Communicate with High Speed GMLAN Device
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Data Link Connector (DLC) Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems |
|||
| 1 | Does the scan tool power up? | Go to Step 2 | Go to Scan Tool Does Not Power Up |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
Go to Step 7 | Go to Step 4 |
| 4 | Test the following circuits of the module that is not communicating for an open or high resistance:
Refer to the following:
Did you find and correct the condition? |
Go to Step 7 | Go to Step 5 |
| 5 | Inspect for poor connections and terminal tension at the following harness connector circuits of the module that is not communicating:
Refer to the following:
Did you find and correct the condition? |
Go to Step 7 | Go to Step 6 |
| 6 |
IMPORTANT:
Perform the programming or setup procedure for the replaced control module, if required. Replace the module that is not communicating on the high speed GMLAN serial data circuit. Refer to Control Module References
in Body Control System for the applicable replacement procedure.Did you complete the replacement? |
Go to Step 7 | - |
| 7 |
|
System OK | Go to Step 2 |