Circuit Description
The exhaust gas recirculation (EGR) valve is vacuum operated. Vacuum for the EGR valve control system is supplied by a belt driven vacuum pump. The EGR valve vacuum control solenoid and the EGR valve vacuum vent solenoid work together to control the position of the EGR valve. The engine control module (ECM) monitors the EGR vacuum sensor signal to determine the amount of vacuum that is applied to the EGR valve. The ECM uses the mass air flow (MAF) sensor to calculate the amount of exhaust gas that is consumed by the engine. When the EGR valve is opened, the MAF rate will decrease. If the EGR vacuum sensor signal is higher than desired and the MAF rate is lower than expected, it is assumed that the EGR valve is not closing due to a vacuum problem and DTC P1404 sets.