Rear Window Defogger Operation
Battery positive voltage is supplied to the RR DEFOG relay switch. Ignition 1 voltage is supplied through the IGN E fuse, in the underhood fuse block, to the RR DEFOG relay coil. When you start the engine, and depress the rear window defogger switch. The HVAC control module illuminates the rear window defogger indicator and energizes the RR DEFOG relay by grounding the control circuit of the relay. This allows battery positive voltage through the RR DEFOG fuse to the rear window defogger grid. Ground for the rear window defogger grid is provided by G420.
When you start the engine and press the rear window defogger switch for the first time, the defogger cycle lasts for 10 minutes. Further operation results in 10 minute defogger cycles.
Battery positive voltage is supplied to the RR DEFOG relay switch. Ignition 1 voltage is supplied through the IGN E fuse, in the underhood fuse block, to the RR DEFOG relay coil. When you start the engine, and depress the rear window defogger switch. The HVAC control assembly illuminates the rear window defogger indicator and energizes the RR DEFOG relay by grounding the control circuit of the relay. This allows battery positive voltage through the RR DEFOG fuse to the rear window defogger grid. Ground for the rear window defogger grid is provided by G420.
When you start the engine and press the rear window defogger switch for the first time, the defogger cycle lasts for 10 minutes. Further operation results in 5 minute defogger cycles. The defogger cycle resets to 10 minutes when you cycle the ignition to the OFF position and then start the engine.