Test Description
WARNING: This page is about a different car, the 2004 Pontiac Aztek and 2004 Buick Rendezvous. However, it is still accessible from the selected car via links, so may be relevant.
This test measures the operating efficiency of the A/C system under the following conditions:
- The current ambient air temperature
- The current relative humidity
- The high side pressure of the A/C system
- The low side pressure of the A/C system
- The temperature of the air being discharged into the passenger compartment
The numbers below refer to the step numbers on the diagnostic table.
- 1: This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
- 2: This step measures the performance of the A/C system.
- 3: This step is to allow for vehicle variations as well as high ambient temperatures.
Air Conditioning (A/C) System Performance Test
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
|
IMPORTANT:
|
||||
| 1 |
|
Greater than 16°C (60°F) - 345 kPa (50 psi) Greater than 24°C (75°F) - 483 kPa (70 psi) Greater than 33°C (90°F) - 690 kPa (100 psi) |
Go to Step 2 | Go to Leak Testing |
| 2 |
IMPORTANT:
Record the relative humidity and the ambient air temperature at the time of the test.
IMPORTANT:
Press the RESET button, before using the print function of the J 43600
. See Special Tools and Equipment .
|
- | Go to Step 8 | Go to Step 3 |
| 3 | If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? |
- | Go to Step 8 | Go to Step 4 |
| 4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperature do not? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A | Go to Step 5 |
| 5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B | Go to Step 6 |
| 6 | Are the low and high side pressures both greater than the specified ranges? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C | Go to Step 7 |
| 7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D | Go to Step 8 |
| 8 | Operate the system in order to verify the test results. Did you find the same results? |
- | System OK | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic |
A/C Performance Table
| Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
|---|---|---|---|---|
| Low Side | High Side | |||
| 13-18°C (55-65°F) | 0-100% | 197-225 kPa (29-33 psi) | 1100-1230 kPa (160-178 psi) | 9°C (48°F) |
| 19-23°C (66-75°F) | Below 40% | 191-228 kPa (28-33 psi) | 1060-1230 kPa (154-178 psi) | 10°C (50°F) |
| Above 40% | 202-246 kPa (29-36 psi) | 1100-1370 kPa (160-199 psi) | 12°C (54°F) | |
| 24-29°C (76-85°F) | Below 35% | 194-230 kPa (28-33 psi) | 1130-1220 kPa (164-177 psi) | 11°C (52°F) |
| 35-60% | 198-246 kPa (29-36 psi) | 1090-1320 kPa (158-191 psi) | 12°C (54°F) | |
| Above 60% | 236-311 kPa (34-45 psi) | 1140-1580 kPa (165-229 psi) | 15°C (59°F) | |
| 30-35°C (86-95°F) | Below 30% | 208-256 kPa (30-37 psi) | 1230-1370 kPa (178-199 psi) | 14°C (57°F) |
| 30-50% | 215-284 kPa (31-41 psi) | 1180-1540 kPa (171-223 psi) | 16°C (61°F) | |
| Above 50% | 236-311 kPa (34-45 psi) | 1290-1750 kPa (187-254 psi) | 18°C (64°F) | |
| 36-40°C (96-105°F) | Below 20% | 235-298 kPa (34-43 psi) | 1340-1600 kPa (194-232 psi) | 17°C (63°F) |
| 20-40% | 246-315 kPa (36-46 psi) | 1340-1700 kPa (194-247 psi) | 18°C (64°F) | |
| Above 40% | 260-348 kPa (38-51 psi) | 1410-1940 kPa (204-281 psi) | 21°C (70°F) | |
| 41-46°C (106-115°F) | Below 20% | 266-339 kPa (39-49 psi) | 1550-1820 kPa (225-264 psi) | 21°C (70°F) |
| Above 20% | 280-369 kPa (41-54 psi) | 1530-2000 kPa (222-290 psi) | 23°C (73°F) | |
| 47-49°C (116-120°F) | Below 30% | 304-378 kPa (44-55 psi) | 1870-2020 kPa (271-293 psi) | 24°C (75°F) |