RECIRCULATION Actuator: Installation
WARNING: This page is about a different car, the 2002 Oldsmobile Intrigue. However, it is still accessible from the selected car via links, so may be relevant.
- Connect the recirculation actuator plunger rod to the recirculation door, then extend the plunger. See Figure. During installation, position the recirculation actuator retaining tab above the mating base on the HVAC control module case.
- Push the vacuum actuator toward the HVAC control module case to secure the retaining tab. Verify that the vacuum actuator pushrod is not binding on the recirculation lever. Connect the vacuum harness connector to the recirculation actuator. Install the I/P compartment. Install the right I/P insulator.