Test R: Head-Up Display Hazard Indicators Inoperative
- If IPC diagnostic system check was performed, go to next step. If IPC diagnostic system check was not performed, go to INSTRUMENT PANEL CLUSTER DIAGNOSTIC SYSTEM CHECK under SELF-DIAGNOSTIC SYSTEM. After performing IPC diagnostic system check, go to next step.
- Check operation of IPC hazard indicators. If IPC hazard indicators are operating properly, problem may be intermittent. To diagnose intermittent, go to INTERMITTENT TROUBLE CODE DETERMINATION in BODY CONTROL MODULES - CORVETTE article. If HUD does not dim properly, go to next step. If IPC hazard indicators are not operating properly, go to next step.
- Turn ignition off. Disconnect IPC connectors. See INSTRUMENT PANEL CLUSTER under REMOVAL & INSTALLATION. Turn ignition on. Turn hazard switch on. Connect test light between ground and IPC connector terminal B6 (Gray/Black wire). See Figure . If test light illuminates, go to next step. If test light does not illuminate, go to step 5 .
- Replace IPC. See INSTRUMENT PANEL CLUSTER under REMOVAL & INSTALLATION. After repairs, go to step 7 .
- Disconnect hazard warning switch connector. See HAZARD WARNING SWITCH under REMOVAL & INSTALLATION. Check for open in Gray/Black wire between IPC connector terminal B6 and hazard warning switch connector terminal "E". Repair as necessary. After repairs, go to step 7 . If circuit is okay, go to next step.
- Replace hazard warning switch. After repairs, go to next step.
- Recheck system operation to verify the repair. If system operates properly, repair is complete. If system does not operate properly, go to step 3 .