Home >> Chevrolet >> 2001 >> Cavalier LS, 2.2 4 >> Repair and Diagnosis >> External Pages >> Different car >> Section 260 (Automatic Transaxle - 4T40-E/4T45-E - Overhaul) >> Description and Operation >> Park or Neutral - Engine Running (W/o Electronic Range Select Mode) >> Pressure Regulation >> Actuator Feed Limit (AFL) Valve

Actuator Feed Limit (AFL) Valve

WARNING: This page is about a different car, the 2004 Pontiac Sunfire, 2004 Chevrolet Classic, and 2004 Chevrolet Cavalier. However, it is still accessible from the selected car via links, so may be relevant.

Line pressure is routed through the valve and into the actuator feed fluid circuit. The valve limits the actuator feed fluid pressure to a maximum pressure. Actuator feed fluid is routed to the pressure control solenoid and to each of the shift valves. The fluid also feeds the 1-2 signal and the 2-3 signal fluid circuits.