Noise Diagnosis - Blower Motor
WARNING: This page is about a different car, the 2004 Pontiac Sunfire and 2004 Chevrolet Cavalier. However, it is still accessible from the selected car via links, so may be relevant.
Noise Diagnosis - Blower Motor
| Step | Action | Yes | No |
|---|---|---|---|
| DEFINITION: Noise originating from the blower motor. | |||
| 1 | Were you sent here from the Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual in HVAC Systems-Manual |
| 2 | Inspect the air inlet grille for debris. Is debris present? |
Go to Step 8 | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 11 |
| 4 | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excess vibration present? |
Go to Step 6 | Go to Step 5 |
| 5 | Listen to the blower motor at each speed. Does the motor make a squeaking or a chirping noise? |
Go to Step 9 | Go to Step 11 |
| 6 | Remove the blower motor. Refer to Blower Motor Replacement . Inspect the blower motor for deposits of foreign material. Did you find any foreign material on the blower motor? |
Go to Step 8 | Go to Step 7 |
| 7 | Inspect the blower motor for the following conditions:
Did you find any of these conditions? |
Go to Step 9 | Go to Step 10 |
| 8 | Remove the foreign material. Is the action complete? |
Go to Step 11 | - |
| 9 | Replace the blower motor. Refer to Blower Motor Replacement . Is the replacement complete? |
Go to Step 11 | - |
| 10 | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete? |
Go to Step 11 | - |
| 11 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Step 2 |