1-2 & 2-3 Shift Solenoid Valves
The 1-2 and 2-3 shift solenoid valves (also called "A" and "B" solenoids) are identical devices that control the movement of the 1-2 and 2-3 shift valves (the 3-4 shift valve is not directly controlled by a shift solenoid). The solenoids are normally open exhaust valves that work in four combinations to shift the transmission into different gears. See SHIFT SOLENOID OPERATION table.
The PCM energizes each solenoid by grounding the solenoid through an internal quad driver. This sends current through the coil winding in the solenoid and moves the internal plunger out of the exhaust position. When ON, the solenoid redirects fluid to move a shift valve.
The PCM-controlled shift solenoids eliminate the need for T.V. and governor pressures to control shift valve operation.
| Gearshift Lever Position | 1-2 Solenoid | 2-3 Solenoid | |||
|---|---|---|---|---|---|
| "OD" (Overdrive) | |||||
| First Gear | On | On | |||
| Second Gear | Off | On | |||
| Third Gear | Off | Off | |||
| Overdrive | On | Off | |||
| "D" (Drive) | |||||
| First Gear | On | On | |||
| Second Gear | Off | On | |||
| Third Gear | Off | Off | |||
| "2" (Intermediate) | |||||
| First Gear | On | On | |||
| Second Gear (1) | Off | On | |||
| "1" (Low) | |||||
| First Gear | On | On | |||
| Second Gear | Off | On | |||
| "R" (Reverse) | On | On | |||
| "N" (Neutral) | On | On | |||
| "P" (Park) | On | On | |||
|
|||||