Diagnostic Aids
A thorough inspection of wiring and connectors is important to prevent misdiagnosis. Check for backed-out terminals, improper mating, broken locks, improperly formed or damaged terminals, poor terminal-to-wiring connections, or damaged wiring harness. An intermittent may be caused by a poor connection, rubbed-through wire insulation, or a broken wire inside insulation.
The following are possible causes of DTC:
- Open in delivered torque circuit.
- Short to ground or voltage in delivered torque circuit.
- Communication frequency problem.
- Communication duty cycle problem.
- Wiring problem, terminal corrosion, or poor connections in delivered torque circuit.
- EBCM not receiving information from PCM.