Temperature Actuator Replacement
REMOVAL PROCEDURE1. Remove the left instrument panel insulator to access the HVAC module.
2. Disconnect the electrical connector to the temperature valve electric actuator.
3. Remove the mounting screws to the temperature valve electric actuator.
4. Remove the temperature valve electric actuator.
INSTALLATION PROCEDURE
1. Install the temperature valve electric actuator.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the mounting screws to the temperature valve electric actuator.
Tighten
Tighten the screws to 1.6 N.m (14 lb in).
3. Connect the electrical connector to the temperature valve electric actuator.
4. Install the left instrument panel insulator.