Turn Signals, High Beam & Seat Belt Indicator Inoperative (Other Indicators & Gauges Okay)
- Disconnect instrument cluster Black 18-pin connector C2. Turn ignition switch to RUN position. Connect test light between battery voltage and instrument cluster harness connector C2, terminal "O" (Black wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 3 .
- Replace instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Recheck system operation.
- Repair poor connection or open in circuit No. 1450 (Black wire) between instrument cluster connector C2 and ground. Recheck system operation.