Inflator
A provision is made to use the compressor to inflate
tires, etc. The inflation equipment consists of the auto level control inflator relay, inflator air switch and auto level control inflator solenoid valve. When the inflator air switch is turned to ON, circuit 1245 is grounded. This energized the inflation timer relay. The inflation timer relay then connects circuit 1249 to voltage, energizing the inflator solenoid, and grounds circuit 321, energizing the compressor relay. These actions divert compressed air to the inflator fill valve rather than to the air shocks. The compressor will continue to run for up to 10 minutes or until the inflator OFF switch is depressed, opening 1245. After approximately 10 minutes of run time, the inflation timer relay will automatically shut off the compressor by opening circuit 1245 and circuit 321. Circuit 1248 is then opened, de-energizing the inflator solenoid and reopening the air path to the air shocks. If the inflation timer relay timer shuts the compressor off in this manner. the system may be restarted by depressing the inflator ON switch.