Air Inlet Actuator
Removal Procedure1. Remove the instrument panel compartment.
2. Disconnect the electrical connector to the air inlet valve electric actuator.
3. Remove the mounting screws from the air inlet valve electric actuator.
4. Remove the air inlet valve electric actuator.
Installation Procedure
1. install the air inlet valve electric actuator.
2. Install the mounting screws to the air inlet valve electric actuator.
Tighten
Tighten the screws to 1.6 N.m (14 lb in).
3. Connect the electrical connector to the air inlet valve electric actuator.
4. install the instrument panel compartment.