Circuit Description
WARNING: This page is about a different variant/trim than selected.
PCM monitors EGR valve pintle position input to ensure that valve responds properly to commands from the PCM. When ignition is turned on, PCM learns the EGR closed valve pintle position. PCM compares the learned EGR closed valve pintle position to the actual position when EGR valve is commanded closed. If actual EGR position indicates that EGR valve is still open when PCM is commanding EGR closed, DTC will set.
Conditions for setting DTC:
- No CKP, ECT, IAT, MAF, MAP, TP or VSS DTC set.
- No misfire, idle speed, fuel injector related DTCs set.
- System voltage 10-16 volts.
- EGR feedback is .2 volt or greater than EGR closed valve pintle position when desired EGR position is commanded to zero percent.
- Conditions present for longer than 20 seconds.