Manual Mode
- Manual mode will automatically be entered after automatic DTC display sequence is complete, or can be entered at any time during the automatic mode by pressing any button on IPC except the E/M (E/M button is used to exit the diagnostic mode at any time).
- When manual mode is selected, IPC will display MANUAL DIAGNOSTICS message for 2 seconds, or until any button on the DIC except the E/M is pressed. After MANUAL DIAGNOSTICS mode message is displayed, IPC will display first system abbreviation and quantity of codes stored for that system, then IPC will wait for further instructions.
- To proceed to next system in the list press OPTIONS button. To go backward in list, press TRIP button. When a system is selected, each DTC for that system can be read by pressing GAGES button to move forward in list, and FUEL button to move backward in list. If no DTCs are present for system currently selected, IPC will display NO MORE CODES and then wait for further instructions.
IPC BUTTON FUNCTIONS
| IPC Button | Function |
|---|---|
| FUEL | Previous DTC |
| GAGES | Next DTC |
| TRIP | Previous System |
| OPTIONS | Next System |
| E/M | Exit Diagnostics |
| RESET | Clear DTCs |