Daytime Running Lamps (DRL) Indicator Inoperative
- Turn ignition switch to "Lock". Disconnect instrument cluster printed circuit connector. Connect a test lamp from instrument cluster printed circuit connector terminal "4" to battery positive terminal. If test lamp lights, go to next step. If test lamp does not light, service/repair open in Black wire between instrument cluster printed circuit and splice.
- Turn ignition switch to RUN. Connect a test lamp from instrument cluster printed circuit terminal "17" to ground. If test lamp lights, replace instrument cluster printed circuit. If test lamp does not light, service/repair open in Light Green/Black wire between instrument cluster printed circuit and daytime running lights (DRL) module.