1. Disconnect the water supply hose (7) from the J 35944-A and bleed any remaining air pressure from the flusher tank (4).

2. Remove the fill cap (9) from the J 35944-A and return any unused flushing solution to its container. Rinse the J 35944-A with water. Do not store the J 35944-A with flushing solution in it.

3. After every third use, clean the J 35944-A as described in the instructions included with the tool.

4. Dispose of any waste water/solution and transmission fluid in accordance with local regulations.