K8A Blower Motor Control Module - Auxiliary X2 (C69)

GM1817814Courtesy of GENERAL MOTORS COMPANY
Connector Part Information
  • Harness Type: Floor Console
  • OEM Connector: 15226103
  • Service Connector: Service by Harness -
  • Description: 2 -Way F 6.3 Series (L-GY)
Terminal Part Information

Terminal Type ID Terminated Lead Diagnostic Test Probe Terminal Removal Tool
I Not required J-35616-42 (RD) No Tool Required
Pin Size Color Circuit Function Terminal Type ID Option
1 0.5 OG 5988 Rear Blower Motor Low Reference I -
2 0.5 BU 101 Blower Motor Control 2 I -