Connecting Rod Bearing Clearance (with Micrometer Gauge Internal Measuring Device)
- Install the connecting bearings and the connecting rod bearing caps.
- Tighten the connecting rod bearing cap bolts in the following sequence:
- First Pass: 25 N.m (18 lb ft)
- Final Pass: 75 degrees - Use the special tool: EN-45059-A Angle Meter
CAUTION:Refer to Fastener Caution .
CAUTION:Refer to TORQUE-TO-YIELD FASTENER CAUTION
Measure the connecting rod bearing diameters at 3 points (1). Use an internal measuring device.
- Calculate the average connecting rod inner diameter.
Formula: (1. result + 2. result + 3. result) / 3
Measure the connecting rod journal diameter at 2 points between (1) and (3) and between (2) and (4). Use a micrometer gauge.
- Calculate the average connecting rod journal diameter.
Formula: (1. result + 2. result) / 2.
- Subtract the average connecting rod journal diameter from the average connecting rod bearing diameter in order to determine the connecting rod bearing clearance.
- Refer to ENGINE MECHANICAL SPECIFICATIONS for the correct value of the connecting rod bearing clearance.