X204 Instrument Panel Harness to HVAC Harness
Connector Part Information
|
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | 84962854 | J-35616-12 (BU) | J-38125-215A |
| II | Not required | J-35616-17 (LT GN) | No Tool Required |
| Pin | Size | Color | Circuit | Terminal Type ID | Option | Function | Pin | Size | Color | Circuit | Terminal Type ID | Option |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 0.35 | BN | 518 | I | - | Lower Left Duct Air Temperature Sensor Signal | 1 | - | - | - | - | - |
| 2 | 0.35 | BN | 516 | I | - | Left Upper Duct Air Temperature Sensor Signal | 2 | 0.35 | BN | 516 | II | - |
| 3 | 0.35 | BN / YE | 520 | I | - | Lower Right Duct Air Temperature Sensor Signal | 3 | 0.35 | BN / YE | 520 | II | - |
| 4 | 0.35 | BN / YE | 517 | I | - | Right Upper Duct Air Temperature Sensor Signal | 4 | 0.35 | BN / YE | 517 | II | - |
| 5 | 0.35 | GY | 6137 | I | - | A/C Evaporator Temperature Sensor Signal | 5 | 0.35 | GY | 6137 | II | - |
| 6 | 0.35 | VT / BK | 339 | I | - | Run/Crank Ignition 1 Voltage | 6 | 0.35 | VT / BK | 339 | II | - |
| 7 | - | - | - | - | - | Not Occupied | 7 | - | - | - | - | - |
| 8 | 0.35 | BK / YE | 407 | I | - | Sensor Low Reference | 8 | 0.35 | BK / YE | 407 | II | - |
| 9 - 12 | - | - | - | - | - | Not Occupied | 9 - 12 | - | - | - | - | - |
| 13 | 0.35 0.5 |
BK BK / WH |
2851 2851 |
I I |
CJ2 -CJ2 |
Signal Ground Signal Ground |
13 | 0.35 0.5 |
BK BK / WH |
2851 2851 |
II II |
CJ2 -CJ2 |
| 14 | 0.35 | GN / VT | 2852 | I | - | Body Control Module LIN Bus 6 | 14 | 0.35 | GN / VT | 2852 | II | - |
| 15 | - | - | - | - | - | Not Occupied | 15 | - | - | - | - | - |
| 16 | 0.35 | WH / YE | 4634 | I | - | HVAC Remote Enable Signal | 16 | 0.35 | RD / WH | 4634 | II | - |