    Each component may need to be disconnected to isolate a short to voltage, short to ground, or an open/high resistance. Use the schematics to identify the following:

    • Accent lamps the vehicle is equipped with
    • Each component's control and ground circuit terminals
    • Component locations on the appropriate control circuit
  1. Ignition OFF, disconnect the module connector on the control side of the inoperative accent lamp.
  2. Verify the accent lamp(s) is not illuminated:
    • If a accent lamp(s) is illuminated 

      Repair the short to voltage on the control circuit.

    • Go to next step: If the accent lamp(s) is not illuminated 
  3. Connect a 3 A fused jumper wire between B+ and the control circuit terminal at the module connector.
  4. Verify the accent lamp(s) are illuminated.
    • If accent lamp(s) are not illuminated and the jumper fuse is OK. 
    1. Test the accent lamp ground circuit for an open/high resistance.
      • If an open/high resistance is found, repair the fault on the circuit or ground connection.
      • Go to next step: If an open/high resistance is not found.
    2. Test the accent lamp control circuit for an open/high resistance.
      • If an open/high resistance is found, repair the fault on the circuit.
      • Go to next step: If an open/high resistance is not found
    3. Replace the appropriate accent lamp.
    • If the accent lamp(s) is not illuminated and the jumper fuse is open 
    1. Test the control circuit or a short to ground.
      • If a short to ground is found, repair the fault on the circuit.
      • Go to next step: If a short to ground is not found
    2. Replace the appropriate accent lamp.
    • Go to next step: If the accent lamp(s) on the appropriate circuit are illuminated 
  5. Replace the control module.