LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2021 >> CT4 Sport, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 57 (Engine Heating And Cooling - Repair Instructions (1 Of 2)) >> Repair Instructions >> Auxiliary Water Pump Outlet Upper Hose Replacement (LSY) >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2022 Cadillac CT4. However, it is still accessible from the selected car via links, so may be relevant.
  1. GM5252758

    Auxiliary Water Pump Outlet Upper Hose (2) - Install NEW

  2. Hose Clamp (1) - Engage - Hose Clamp Replacement Guidelines - Spring Type 
  3. GM5251989

    Water Inlet Gasket (2) - Install NEW

  4. Install the engine coolant thermostat housing pipe (1) into the auxiliary water pump outlet hose and then install the engine coolant thermostat housing pipe to the engine block.
  5. GM5251871
    CAUTION:

    Refer to Fastener Caution .

    Engine Coolant Thermostat Housing Bolt (2) - Install [3x] - Fastener Specifications

  6. Hose Clamp (1) - Engage - Hose Clamp Replacement Guidelines - Spring Type 
  7. GM5324136

    Engine Coolant Temperature Sensor Electrical Connector (1) @ Engine Coolant Thermostat Housing Inlet Pipe - Connect

  8. GM5324124

    Turbocharger Coolant Feed Hose (2) @ Engine Coolant Thermostat Housing Inlet Pipe - Install

  9. Hose Clamp (1) - Engage - Hose Clamp Replacement Guidelines - Spring Type 
  10. GM5405482

    Air Cleaner Assembly (1) - Install

  11. GM5405481

    Air Cleaner Bolt (1) - Install and tighten - Fastener Specifications

  12. Connect the electrical connector and install all wiring harnesses to the air cleaner assembly.
  13. GM5405476

    Air Cleaner Outlet Duct (1) - Install

  14. Connect the electrical connector.
  15. GM5405472

    Positive Crankcase Ventilation Tube (3) - Connect - Plastic Collar Quick Connect Fitting Service

  16. Evaporative Emission Canister Purge Tube (2) - Connect - Plastic Collar Quick Connect Fitting Service
  17. Air Cleaner Outlet Duct Clamp (1) - Tighten [2x] - Fastener Specifications
  18. Fill the cooling system. Refer to Cooling System Draining and Filling (LSY GE 47716) , or Cooling System Draining and Filling (LSY Static Fill) , or Cooling System Draining and Filling (LSY with V03 Static Fill) , or Cooling System Draining and Filling (LSY with V03 GE 47716) 
  19. Start the engine and check for coolant leaks.