Cleaning and Inspection Procedure - Conditional
WARNING: This page is about a different car, the 2022 Cadillac CT4. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
The following cleaning and inspection and/or overhaul steps are ONLY to be performed as determined necessary based on the condition of the part being removed with the intention of reinstallation. The labor time to perform any of these steps is not included in the base labor time and if required would need to be documented and submitted as Other Labor Hours for warranty claim reimbursement. A description of the repairs performed must be documented in the technician correction comments.
- NOTE:
Do not soak or submerge the camshaft position actuator magnet in solvent.
Clean the camshaft position actuator magnet electrical connector and mounting surface of dirt, debris or contamination.
- Dry the camshaft position actuator magnet with compressed air.
- Inspect the camshaft position actuator magnet for the following conditions:
- Damage to the sealing surface (1)
- Damage to the electrical connector (2)
- Damage to the mounting holes (3)
- Depress the valve (4) into the housing. The valve should move freely with no binding or sticking and minimal resistance inward.
- If any of the above conditions exist, replace the camshaft position actuator magnet.
WARNING: