Circuit/System Testing
WARNING: This page is about a different car, the 2022 Cadillac CT4. However, it is still accessible from the selected car via links, so may be relevant.
Starter Test
- Verify a test lamp illuminates between the B+ terminal A X2 at the M64 Starter and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Test the B+ circuit 442 for an open/high resistance.
- If an open/high resistance is found, repair the fault on the circuit.
- Go to next step: If an open or high resistance is not found
- Verify the fuse is good and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Test the B+ circuit 442 a short to ground
- If a short to ground is found, repair the fault on the circuit.
- Go to next step: If a short to ground is not found
- Replace the M64 Starter.
- Go to next step: If the test lamp illuminates
- Ignition OFF and all vehicle systems off, disconnect the KR27 Starter Relay.
- Verify a test lamp illuminates between ground circuit terminal 86 and B+.
- If the test lamp does not illuminate
- Repair the open/high resistance on circuit 6450 or ground connection.
- Go to next step: If the test lamp illuminates
- Ignition on, connect a test lamp between the control circuit terminal 85 and ground.
- Verify the test lamp turns ON and OFF while commanding the Starter Motor ON and OFF with the scan tool.
- If the test lamp is always OFF
- Test circuit 625 for a short to ground.
- If a short to ground is found, repair the fault on the circuit.
- Go to next step: If a short to ground is not found
- Test circuit 625 for an open/high resistance.
- If an open/high resistance is found, repair the fault on the circuit.
- Go to next step: If an open/high resistance is not found
- Replace the K20 Engine Control Module.
- If the test lamp is always ON
- Test circuit 625 for a short to voltage.
- If a short to voltage is found, repair the fault on the circuit.
- Go to next step: If a short to voltage is not found
- Replace the K20 Engine Control Module.
- Go to next step: If the test lamp turns ON and OFF
- Verify a test lamp illuminates between the B+ circuit terminal 87 and ground.
- If the test lamp does not illuminate and the fuse is good
Replace the X50A Fuse Block - Underhood.
- If the test lamp does not illuminate and the fuse is open
- Test circuit 6 for a short to ground.
- If a short to ground is found, repair the fault on the circuit.
- Go to next step: If a short to ground is not found
- Replace the M64 Starter.
- Go to next step: If the test lamp illuminates.
- If the test lamp does not illuminate and the fuse is good
- Ensure the parking brake is applied and the automatic transmission is in PARK or manual transmission in NEUTRAL. Momentarily install a 30 A fused jumper between B+ circuit terminal 87 and control circuit terminal 30.
- Verify the M64 Starter Motor Spins.
- If the starter spins
Replace the KR27 Starter Relay.
- Go to next step: If the starter does not spin
- If the starter spins
- Replace the M64 Starter.