Component Testing
Relay Test
- Ignition OFF, disconnect the KR147 Instrument Panel Compartment Door Unlatch Actuator Relay.
- Test for 60 - 200 Ω between terminals 1 and 3.
- If less than 60 Ω or greater than 200 Ω
Replace the KR147 Instrument Panel Compartment Door Unlatch Actuator Relay.
- Go to next step: If between 60 - 200 Ω
- If less than 60 Ω or greater than 200 Ω
- Test for infinite resistance between the terminals listed below:
- 4 and 1
- 4 and 5
- 4 and 3
- 3 and 5
- If less than infinite resistance
Replace the KR147 Instrument Panel Compartment Door Unlatch Actuator Relay.
- Go to next step: If infinite resistance
- Install a 3 A fused jumper wire between relay terminal 1 and 12 V. Install a jumper wire between relay terminal 3 and ground.
- Test for less than 2 Ω between terminals 4 and 5.
- If 2 Ω or greater
Replace the KR147 Instrument Panel Compartment Door Unlatch Actuator Relay.
- Go to next step: If less than 2 Ω
- If 2 Ω or greater
- All OK
Instrument Panel Compartment Door Release Switch
- Ignition OFF, disconnect the harness connector at the S48D Multifunction Switch 2 - Instrument Panel.
- Test for infinite resistance between the signal terminal 7 and the ground terminal 1 with the switch in the open position.
- If less than infinite resistance
Replace the S48D Multifunction Switch 2 - Instrument Panel.
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 3 Ω between the signal terminal 7 and the ground terminal 1 with the switch in the closed position.
- If 3 Ω or greater
Replace the S48D Multifunction Switch 2 - Instrument Panel.
- Go to next step: If less than 3 Ω
- If 3 Ω or greater
- All OK.
Instrument Panel Compartment Door Release Actuator
- Ignition OFF, disconnect the harness connector at the M91 Instrument Panel Compartment Door Unlatch Actuator.
- Install a 10 A fused jumper wire between the control terminal 1 and 12 V. Install a jumper wire between the ground terminal 2 and ground.
- Verify the M91 Instrument Panel Compartment Door Unlatch Actuator activates.
- If the M91 Instrument Panel Compartment Door Unlatch Actuator does not activate.
Replace the M91 Instrument Panel Compartment Door Unlatch Actuator.
- Go to next step: If the M91 Instrument Panel Compartment Door Unlatch Actuator does activate.
- If the M91 Instrument Panel Compartment Door Unlatch Actuator does not activate.
- All OK.