Typical Scan Tool Data
Transmission Accumulator Solenoid Valve Control Circuit High Voltage Test Status
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine = Running Parameter Normal Range: OK or Not Run |
|||
| B+ circuit Terminal 2 @ X175 | OK | OK | Malfunction |
| Control circuit Terminal 8 @ X175 | OK | OK | Malfunction |
Transmission Accumulator Solenoid Valve Control Circuit Low Voltage Test Status
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine = Running Parameter Normal Range: OK or Not Run |
|||
| B+ circuit Terminal 2 @ X175 | Malfunction | OK | OK |
| Control circuit Terminal 8 @ X175 | Malfunction | OK | OK |
Transmission Accumulator Solenoid Valve Control Circuit Open Test Status
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine = Running Parameter Normal Range: OK or Not Run |
|||
| B+ circuit Terminal 2 @ X175 | OK | Malfunction | OK |
| Control circuit Terminal 8 @ X175 | OK | Malfunction | OK |