Component Testing
Static Test
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector: Q77 Transmission Control Solenoid Valve
- Test for the resistance listed below between the test points: Control Terminal 1 & Control Terminal 2
- Q77 Transmission Control Solenoid Valve - 4, 5 = 4.5 to 5.5 ohms
- Q77H Transmission Control Solenoid Valve 8 = 11.0 to 13.0 ohms
- If the resistance is not within range
Replace the appropriate component: Q77 Transmission Control Solenoid Valve
- Go to next step: If the resistance is within range
- Test for infinite resistance between the test points: Each Terminal of the component & The component's housing - Q77 Transmission Control Solenoid Valve
- If less than infinite resistance
Replace the appropriate component: Q77 Transmission Control Solenoid Valve
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK.
NOTE:
The component's temperature should be 19 to 21°C (66 to 70°F) while testing.