LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2019 >> ATS Base, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 7 (ENGINE MECHANICAL - 3.6L (LGX LF4) - REPAIR INSTRUCTIONS - OFF VEHICLE (2 Of 2)) >> Repair Instructions - Off Vehicle >> Turbocharger Wastegate Actuator Vacuum Tank Installation >> Turbocharger Wastegate Actuator Vacuum Tank Assembly Installation

Turbocharger Wastegate Actuator Vacuum Tank Assembly Installation

WARNING: This page is about a different variant/trim than selected.
GM4037127Courtesy of GENERAL MOTORS COMPANY
Turbocharger Wastegate Actuator Vacuum Tank Assembly Installation

Callout Component Name
1 Turbocharger Wastegate Actuator Vacuum Tank Assembly
NOTE:

Ensure the Wastegate vacuum connection is fully secure and seated. A poor connections can result in a DTC and lead to misdiagnosis.

2 Turbocharger Wastegate Actuator Vacuum Tank Bracket Bolt
CAUTION:

Refer to Fastener Caution .


Tighten 
10 N.m (89 lb in)