Static Test
- Ignition/Vehicle - Off
- Disconnect the electrical connector:Q44 Engine Oil Pressure Control Solenoid Valve
- Test for 10 to 30 Ω between the test points:Control terminal 2/B & Ignition terminal 1/A
- If not between 10 to 30 Ω
Replace the component:Q44 Engine Oil Pressure Control Solenoid Valve
- Go to next step: If between 10 to 30 Ω
- If not between 10 to 30 Ω
- Test for infinite resistance between the test points:Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component:Q44 Engine Oil Pressure Control Solenoid Valve
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK.