Dynamic Test
- Ignition/Vehicle - Off
- Disconnect the electrical connector:Q44 Engine Oil Pressure Control Solenoid Valve
- Connect a 3 A fused jumper wire between the test points:Ignition terminal 1/A & 12 V
- Momentarily connect a jumper wire between the test points:Control terminal 2/B & GroundCAUTION: Complete the testing as quickly as possible in order to prevent overheating and damaging the component.
Verify the component turns On and Off when connecting and disconnecting the jumper wire:Q44 Engine Oil Pressure Control Solenoid Valve
- If the component does not turn On and Off
Replace the component:Q44 Engine Oil Pressure Control Solenoid Valve
- Go to next step: If the component turns On and Off
- If the component does not turn On and Off
- All OK.