Circuit/System Testing
- Ignition OFF, disconnect the X5 harness connector at the K9 Body Control Module.
- Connect a 3 A fused jumper between the control circuit terminal 10 and Ground, ignition ON.
- Verify a test lamp illuminates between the F94UA Fuse test point and ground.
- If the test lamp does not illuminate
- Ignition OFF, disconnect the X3 harness connector at the X50A Fuse Block - Underhood.
- Test for less than 1 V between the control circuit terminal and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the X50A Fuse Block - Underhood.
- Go to next step: If the test lamp illuminates
- Ignition OFF, remove the fused jumper wire
- Ignition ON, verify the test lamp does not illuminate between the F94UA Fuse test point and ground
- If the test lamp illuminates
- Ignition OFF, disconnect the X3 harness connector at the X50A Fuse Block - Underhood.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the X50A Fuse Block - Underhood
- Go to next step: If the test lamp does not illuminate
- Replace the K9 Body Control Module