LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2018 >> Escalade Base, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 8 (Engine Controls And Fuel - 6.0L (L96) - Repair Instructions) >> Repair Instructions >> Air Cleaner Resonator Outlet Duct Replacement >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2018 Chevrolet Suburban 3500 HD. However, it is still accessible from the selected car via links, so may be relevant.
    Fig 1: Air Cleaner Outlet Duct And Clamps
    GM1696567Courtesy of GENERAL MOTORS COMPANY
  1. Install the air cleaner outlet duct to the throttle body and MAF/IAT sensor. Ensure that the resonator tab aligns with the stud on the intake manifold.
  2. Push down on the air cleaner outlet duct resonator directly over the resonator tab in order to secure the resonator to the stud on the intake manifold.
  3. CAUTION:

    Refer to Fastener Caution

    NOTE:

    Ensure the outlet duct is fully seated to the mating surfaces before clamping. Verify that the cuff is not rolled under.

  4. Tighten the air cleaner outlet duct clamp (2) at the throttle body to 4 N.m (35 lb in).
  5. Tighten the air cleaner outlet duct clamp (1) to 4 N.m (35 lb in) at the MAF/IAT sensor.
  6. Install the radiator inlet hose clamp retainer to the outlet duct.
  7. Fig 2: PCV Tube
    GM1696754Courtesy of GENERAL MOTORS COMPANY
  8. Install the PCV line (1) to the air cleaner outlet duct.
  9. NOTE:

    Ensure that all duct(s) have been routed, installed and secured properly.

  10. Install the intake manifold sight shield. Refer to Upper Intake Manifold Sight Shield Replacement .