Torque Converter Housing With Fluid Pump Removal
WARNING: This page is about a different car, the 2018 GMC Yukon XL, 2018 GMC Yukon, 2018 Chevrolet Tahoe, 2018 Chevrolet Suburban 3500 HD, and 2018 Chevrolet Suburban. However, it is still accessible from the selected car via links, so may be relevant.
| Callout | Component Name |
|---|---|
|
CAUTION:
The valve body assembly must be removed prior to removing the torque converter (with fluid pump) housing assembly. Failure to ensure this will cause severe damage to both fluid pump seal assemblies. Also, the load of the valve body pushing on the seals, which in turn push on the pump, may prevent proper pump installation into the case. Refer to control valve body assembly removal.
|
|
| 1 | Turbine Shaft Seal
NOTE:
Remove and DISCARD the seal.
|
| 2 | Torque Converter Housing Bolt (Qty: 9) |
| 3 | Torque Converter with Fluid Pump Housing Assembly |
| 4 | Automatic Transmission Fluid Pump Seal
NOTE:
Remove and DISCARD the seal.
|