Approximate Fluid Capacities
Refrigerant System Capacities
| Application | Specification | |
|---|---|---|
| Metric | English | |
| Abrupt Refrigerant Loss (With V4U) | 60 ml1 | 2.0 oz1 |
| Abrupt Refrigerant Loss (Without V4U) | 45 ml1 | 1.5 oz1 |
| Compressor Replacement | ||
|
NOTE:
The service compressor is precharged with the following amount of PAG oil. Refer to the instruction sheet included with the service compressor.Compressor failure can occur if the oil removed during refrigerant recovery is not replaced. |
41 ml2 | 1.4 oz2 |
| Condenser Replacement (With V4U) | 60 ml2 | 2.0 oz2 |
| Condenser Replacement (Without V4U) | 45 ml2 | 1.5 oz2 |
| Evaporator Replacement (With V4U) | 60 ml2 | 2.0 oz2 |
| Evaporator Replacement (Without V4U) | 45 ml2 | 1.5 oz2 |
| Any Line Set (Hose/Tube or Tube Assembly) Replacement (With V4U) | 30 ml2 | 1.0 oz2 |
| Any Line Set (Hose/Tube or Tube Assembly) Replacement (Without V4U) | 23 ml2 | 0.8 oz2 |
| Total System PAG Oil Capacity (With V4U) | 200.0 ml | 6.8 oz |
| Total System PAG Oil Capacity (Without V4U) | 150.0 ml | 5.1 oz |
| R-134a (Without KRV) | ||
|
0.68 kg | 1.50 lb |
| R-1234yf (With KRV) | ||
|
0.60 kg | 1.30 lb |
| 1
Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. 2 If more than the specified amount of PAG oil was drained from a component, add the amount drained. |
||