Approximate Fluid Capacities
Refrigerant System Capacities
| Application | Specification | |
|---|---|---|
| Metric | English | |
| Abrupt Refrigerant Loss | 60 ml1 | 2.0 oz1 |
| Compressor Replacement | ||
|
NOTE:
The service compressor is precharged with the following amount of PAG oil. Refer to the instruction sheet included with the service compressor.Compressor failure can occur if the oil removed during refrigerant recovery is not replaced. |
41 ml2 | 1.4 oz2 |
| Condenser Replacement | 30 ml2 | 1.0 oz2 |
| Evaporator Replacement | 90 ml2 | 3.0 oz2 |
| Any Line Set (Hose/Tube or Tube Assembly) Replacement | 30 ml2 | 1.0 oz2 |
| Total System PAG Oil Capacity (Without V4U) | 110.0 ml | 3.7 oz |
| Total System PAG Oil Capacity (With V4U) | 230.0 ml | 7.8 oz |
| R-134a (Without KRV, with V4U) | ||
|
0.68 kg | 1.50 lb |
| R-1234yf (With KRV, without V4U) | ||
|
0.60 kg | 1.30 lb |
| 1
Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. 2 If more than the specified amount of PAG oil was drained from a component, add the amount drained. |
||