Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, remove the Q8 Control Solenoid Valve Assembly.
- Verify the Q8 Control Solenoid Valve Assembly is not contaminated with any debris. Refer to Control Solenoid Valve and Transmission Control Module Assembly Inspection .
- If contaminated
Clean as necessary.
- If not contaminated
- If contaminated
- Verify the resistance is within the specified range for each solenoid. Refer to Control Solenoid Valve and Transmission Control Module Assembly Inspection .
- If resistance is not within range
Replace the Q8 Control Solenoid Valve Assembly.
- If resistance is within range
- If resistance is not within range
- Place the Q8 Control Solenoid Valve Assembly on a clean work surface near the transmission assembly.
- Connect DT-47825-10 jumper harness between the vehicle wire harness electrical connector and the Q8 Control Solenoid Valve Assembly electrical connector. Ignition ON.
- Verify the scan tool the parameters listed below do not display Malfunction:
- Line Pressure Control Solenoid Valve Performance Test Status
- Line Pressure Control Solenoid Valve Control Circuit High Voltage Test Status
- Line Pressure Control Solenoid Valve Control Circuit Low Voltage Test Status
- If Malfunction is displayed
Replace the Q8 Control Solenoid Valve Assembly.
- If Malfunction is not displayed
- All OK.
NOTE:
You must perform the Circuit/System Verification first.